Home > Product > Product series classification > 200W series
NEW product Product series classification Authentication class
200W series 250W series 300W series 400W series
N200V5-M N200V5-M

Output power: 200W Max

Leakage Current: <1mA(Vin:230)

Working Temperature: -30℃~60℃

Heat dissipation method: Natural cooling

Storing temperature: -40~80℃

Input voltage: 200-240Vac,47-63Hz

Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac;  O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Output short circuit protection,Input under-voltage recovery point,Output current limiting protection point

Efficiency factor: 0.4@230Vac

Dimension L*W*H (mm): 140×59×30±0.5

N200V5-B N200V5-B

Output power: 200W Max

Leakage Current: <1mA(Vin:230)

Working Temperature: -30℃~60℃

Heat dissipation method: Natural cooling

Storing temperature: -40~80℃

Input voltage: 200-240Vac,47-63Hz

Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac;  O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Output short circuit protection,Input under-voltage recovery point, Output current limiting protection point

Efficiency factor: 0.45@230Vac

Dimension L*W*H (mm): 190×82×30±0.5

JPS200PV5.0-M JPS200PV5.0-M

Output power: 200W Max

Leakage Current: <1mA(Vin:230)

Working Temperature: -30℃~50℃

Heat dissipation method: Natural cooling

Storing temperature: -40~80℃

Input voltage: 100-240Vac,47-63Hz

Insulation Voltage: I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection

Efficiency factor: 0.95@230Vac

Dimension L*W*H (mm): 140×60×30±0.5

JPS200V JPS200V

Output power: 200W Max

Leakage Current: <1mA(Vin:230)

Working Temperature:  -30℃~50℃

Heat dissipation method: Air cooling

Storing temperature: -40~80℃

Input voltage: 110/220Vac(manual button adjustment),47-63Hz

Insulation Voltage: I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection

Efficiency factor: 0.50@230Vac

Dimension L*W*H (mm): 217×117×30±0.5

JPS200P JPS200P

Output power: 200W Max

Leakage Current: <1mA(Vin:230)

Working Temperature: -30℃~60℃

Heat dissipation method: Natural cooling

Storing temperature: --40~80℃

Input voltage: 100-240Vac,47-63Hz

Insulation Voltage: I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection

Efficiency factor: 0.95@230Vac

Dimension L*W*H (mm): 208×60×30±0.5

N200V4.5-D N200V4.5-D

Output power: 200W Max

Leakage Current: <1mA(Vin:230)

Working Temperature: -30℃~50℃

Heat dissipation method: Natural cooling

Storing temperature: -40~80℃

Input voltage: 200-240Vac,47-63Hz

Insulation Voltage: I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection

Efficiency factor: 0.50@230Vac

Dimension L*W*H (mm): 170×60×30±0.5

N200V5-A N200V5-A

Output power: 200W Max

Input voltage: 200-240Vac,47-63Hz

Leakage Current:  <1ma(Vin:230)
Working Temperature: -30℃~60℃

Heat dissipation method: Natural cooling

Storing temperature: -40~80℃
Insulation Voltage:I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac

Safety Standard: GB4943,EN60950

Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection
Efficiency factor: 0.50@230Vac

Dimension L*W*H (mm): 190×84×30±0.5

N200V5-C N200V5-C
Output power: 200W Max
Leakage Current: <1ma(Vin:230)
Working Temperature: -30℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 200-240Vac,47-63Hz
Insulation Voltage:  I/P-O/P:3,OKVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection
Efficiency factor: 0.50@230Vac
Dimension L*W*H (mm): 160×82×30±0.5