JPS400PV5.0A43
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -30℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 100-240Vac,47-63Hz
Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac; O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Output short circuit protection, Input under-voltage recovery point,Output current limiting protection point
Efficiency factor: 0.95@230Vac
Dimension L*W*H (mm): 180×55×26±0.5
JPS400PV5.0A7
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -30℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 100-240Vac,47-63Hz
Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac; O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Output short circuit protection, over temperature protection,Input under-voltage recovery point,Output current limiting protection poin
Efficiency factor: 0.95@230Vac
Dimension L*W*H (mm): 220×47×26±0.5
JPS400PV4.0-3.2A79
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -40℃~70℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 100-240Vac,47-63Hz
Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac; O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Output short circuit protection, Input under-voltage recovery point,Output current limiting protection point
Efficiency factor: 0.95@230Vac
Dimension L*W*H (mm): 180×68×26±0.5
JPS400PV4.0-3.2A39A
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -40℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 100-240Vac,47-63Hz
Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac; O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Output short circuit protection, Input under-voltage recovery point,Output current limiting protection point
Efficiency factor: 0.95@230Vac
Dimension L*W*H (mm): 240×65×26±0.5
JPS400PV4.2-3.2A57
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -30℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 100-240Vac,47-63Hz
Insulation Voltage: I/P-O/P:3.0KVac; I/P-FG: 1.5KVac; O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Output short circuit protection, Input under-voltage recovery point,Output current limiting protection point
Efficiency factor: 0.95@230Vac
Dimension L*W*H (mm): 180×68×26±0.5
JPS400PV5.0
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -30℃~70℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Input voltage: 100-240Vac,47-63Hz
Protection: Input under-voltage protection, Output short circuit protection, Input under-voltage recovery point,Output current limiting protection point
Efficiency factor: 0.95@230Vac
Dimention L*W*H (mm): 220×52×26.5±0.5
J400PV4.2-3.2A2
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -30℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~85℃
Input voltage: 200-240Vac,47-63Hz
Protection: Output short circuit protection(V01 96-150V), Output current limiting protection point
Efficiency factor: 0.95@230Vac
Dimention L*W*H (mm): 220×52×26.5±0.5
J400PV5.0A7
Output power: 400W Max
Input voltage: 200-240Vac,47-63Hz
Leakage Current: <1ma(Vin:230)
Working Temperature: -30℃~60℃
Heat dissipation method: Natural cooling
Storing temperature: -40~80℃
Protection: Input under-voltage protection, Output short circuit protection,Output current limiting protection point,over-temperature protection
Efficiency factor: 0.95@230Vac
Dimension L*W*H (mm): 220×47×26±0.5
JPS400V
Output power: 400W Max
Leakage Current: <1mA(Vin:230)
Working Temperature: -30℃~50℃
Heat dissipation method: Air cooling
Storing temperature: -40~80℃
Input voltage: 110/220Vac(manual button adjustment),47-63Hz
Insulation Voltage: I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950
Protection: Input under-voltage protection, Overload Protection (OLP), Output short circuit protection
Efficiency factor: 0.50@230Vac
Dimension L*W*H (mm): 217×117×30±0.5
J400V5
Insulation Voltage: I/P-O/P:3.0KVac;I/P-FG:1.5KVac;O/P-FG:0.5KVac
Safety Standard: GB4943,EN60950